Product line · DSS & DSSD

Constant temperature & humidity, in one cabinet.

Cooling, heating, humidifying and dehumidifying from a single controller — held to ±1 °C and ±5 %RH. Split cabinet units for plant rooms, or concealed ceiling units where floor space has to stay clear.

DSS cabinet constant temperature and humidity unit with outdoor condensing unit
2.5 → 25 kW
Cooling capacity
±1 °C
Temperature band
±5 %RH
Humidity band
14
Cabinet and ceiling models

01Two mounting forms

Same control platform. Two ways to install it.

Both formats are split systems: an indoor unit holding the coil, humidifier, fan and controller, and an outdoor condensing unit. The choice is about where the indoor unit can live, not about performance.

DSS cabinet unit beside its outdoor condensing unit

DSS series · cabinet

Floor-standing cabinet

For plant rooms, laboratories, archives and stores where a service aisle is available. Front access to filters, humidifier cylinder and controls; condensate pumped or drained by gravity.

  • 1,680 mm or 1,800 mm cabinet height
  • Side or rear duct connection for distributed air
  • Outdoor unit on a wall bracket, roof or deck
DSSD concealed ceiling constant temperature and humidity unit with louvred discharge

DSSD series · ceiling

Concealed above the ceiling

The indoor unit sits in the ceiling void at 242 to 630 mm deep, with the louvred fascia flush to the finished ceiling. Nothing occupies the floor, which is what makes it usable in finished interiors.

  • 242 mm deep on the 1P to 2P models
  • Internal circulation — no outdoor-air duct needed
  • Condensate lift available for tight voids

02What the unit does

Four functions, one controller.

A dehumidifier removes moisture. A humidistat adds it. This unit does both, and moves the temperature as well — which is the point in a room where the band is narrow in both directions.

01

Cooling

DX coil and outdoor condensing unit sized to the room load, not to the dehumidification duty alone.

02

Heating

Electric heating stage holds the temperature when the moisture load is high but the sensible load is not.

03

Humidification

Electrode humidifier from 1 to 15 kg/h, called by the same controller that runs the dehumidification side.

04

Dehumidification

From 2 to 20 kg/h at 30 °C / 80 %RH, with low-temperature defrost on the cooling coil.

03Control & protection

Set the band once, then leave it.

The controller reads temperature and humidity continuously and decides which function runs. Operators see the set point, the actual reading and any fault code on one screen — no separate humidistat, thermostat or timer to keep in step.

For projects that need it, the same board exposes a remote communication interface for BMS or a site supervisor.

  • Temperature and RH shown live, set point adjustable on the panel
  • 7-day timer and automatic restart after power failure
  • Compressor delay and phase-sequence protection
  • Low-temperature defrost, fault-code self-diagnosis
  • Silver-ion dust filter on the return air
  • Remote communication available to order
Dehumidify and humidify cabinet with controller interface
The DHS dehumidify + humidify cabinet uses the same control family.See DHS models.

04Model range

Published data, both series.

Dehumidification figures are quoted at 30 °C / 80 %RH. Power values are running figures at nominal conditions; the final nameplate is issued against the confirmed model and destination market.

DSS · Cabinet units

Model Cooling Dehumid. Humid. Airflow Cool kW Humid kW Heat kW Total kW Supply Indoor L×W×H mm Outdoor L×W×H mm
DSS1.5P3,500 W5 kg/h2–4 kg850 m³/h1.200.303.004.50220 V470×650×1680780×260×540
DSS2P5,000 W7 kg/h2–4 kg1,000 m³/h1.750.304.006.05220 V470×650×1680840×285×610
DSS3P7,500 W9 kg/h3–6 kg2,000 m³/h2.750.506.009.25220/380 V470×800×1800840×310×710
DSS5P12,500 W12 kg/h6–9 kg3,000 m³/h3.750.609.0013.35380 V470×800×1800720×760×930
DSS6P15,000 W14 kg/h6–9 kg4,000 m³/h5.500.6012.0018.10380 V470×800×1800720×760×930
DSS8P20,000 W16 kg/h12–15 kg5,000 m³/h6.500.8015.0022.30380 V470×1200×18001420×760×930
DSS10P25,000 W20 kg/h12–15 kg6,000 m³/h7.500.8018.0026.30380 V470×1200×18001420×760×930

DSSD · Concealed ceiling units

Model Cooling Dehumid. Humid. Cool kW Total kW Supply Indoor L×W×H mm Outdoor L×W×H mm
DSSD1P2,500 W2–3 kg/h1–2 kg/h1.205.90220 V1045×670×242840×285×610
DSSD1.5P3,500 W4–6 kg/h2–4 kg/h1.505.90220 V1045×670×242840×285×610
DSSD2P5,000 W5–7 kg/h2–4 kg/h2.007.00220 V1045×670×242840×285×610
DSSD3P7,500 W7–9 kg/h3–5 kg/h3.0015.00220 V1030×570×375840×285×610
DSSD5P12,500 W10–12 kg/h5–8 kg/h5.0017.00380 V1030×570×375760×720×930
DSSD6P15,000 W10–12 kg/h5–8 kg/h5.5021.50380 V1030×570×375760×720×930
DSSD10P25,000 W15–20 kg/h5–8 kg/h8.0028.00380 V1200×1245×6301420×760×930

All figures at 30 °C / 80 %RH unless stated. Dimensions are the indoor and outdoor units in transport order L×W×H in millimetres. 60 Hz and 110–240 V builds available to order.

05Where it is used

Rooms that have to hold a band, not just stay dry.

These are the duties the unit is normally specified for — a target temperature and a target humidity at the same time, in a room where nobody is watching the controller.

01Laboratories & test roomsStable band during test cycles
02Archives & paper storesRH band, no condensation
03Storage & material roomsSeasonal dry / humid switching
04Cigar roomsNarrow RH band, year round
05Wine cellarsCool and humid, held together
06Instruments & electronicsDry air without heat build-up

06Request

Tell us the room, we size the unit.

Room volume, the temperature and humidity you have to hold, the moisture load from people and process, and the electrical supply on site. With those four we can pick a model and tell you which one we rejected and why.

Or send it directly toleo@hzdeyoujiang.cn.